Spatz: the time-of-flight neutron reflectometer with vertical sample geometry at the OPAL research reactor
dc.contributor.author | Le Brun, AP | en_AU |
dc.contributor.author | Huang, TY | en_AU |
dc.contributor.author | Pullen, SA | en_AU |
dc.contributor.author | Nelson, ARJ | en_AU |
dc.contributor.author | Spedding, J | en_AU |
dc.contributor.author | Holt, SA | en_AU |
dc.date.accessioned | 2024-12-05T02:12:49Z | en_AU |
dc.date.available | 2024-12-05T02:12:49Z | en_AU |
dc.date.issued | 2023-02 | en_AU |
dc.date.statistics | 2024-08-28 | en_AU |
dc.description.abstract | The Spatz neutron beam instrument is the second time-of-flight neutron reflectometer to be installed at the OPAL research reactor. The instrument was formerly the V18 BioRef reflectometer at the BER-II reactor in Berlin and was transferred to Australia in 2016. Subsequently the instrument was re-installed in the neutron guide hall of the OPAL reactor at the end position of the CG2B cold-neutron guide and recommissioned. The instrument performance has not been compromised by the move, with reflectivity achieved down to 10−7 and good counting statistics within a reasonable time frame using a wavelength range of 2–20 Å. Several different samples at the solid–air interface and the solid–liquid interface have been measured to demonstrate the instrument's capabilities. © The Authors - CC BY 4.0. | en_AU |
dc.description.sponsorship | ANSTO is extremely grateful to HZB for the gift of the V18 BioRef instrument. The authors thank the many engineers, technicians, scientists and others who worked on transferring and installing Spatz. Open access publishing facilitated by Australian Nuclear Science and Technology Organisation, as part of the Wiley – Australian Nuclear Science and Technology Organisation agreement via the Council of Australian University Librarians. | en_AU |
dc.format.medium | Electronic-eCollection | en_AU |
dc.identifier.citation | Le Brun, A. P., Huang, T.-Y., Pullen, S., Nelson, A. R. J., Spedding, J., & Holt, S. A. (2023). Spatz: the time-of-flight neutron reflectometer with vertical sample geometry at the OPAL research reactor. Journal of Applied Crystallography, 56(1), 18-25. doi:10.1107/S160057672201086X | en_AU |
dc.identifier.issn | 0021-8898 | en_AU |
dc.identifier.issn | 1600-5767 | en_AU |
dc.identifier.issue | 1 | en_AU |
dc.identifier.journaltitle | Journal of Applied Crystallography | en_AU |
dc.identifier.pagination | 18-25 | en_AU |
dc.identifier.uri | https://doi.org/10.1107/s160057672201086x | en_AU |
dc.identifier.uri | https://apo.ansto.gov.au/handle/10238/15767 | en_AU |
dc.identifier.volume | 56 | en_AU |
dc.language | eng | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | International Union of Crystallography | en_AU |
dc.subject | Research reactors | en_AU |
dc.subject | Geometry | en_AU |
dc.subject | Neutron beams | en_AU |
dc.subject | OPAL Reactor | en_AU |
dc.subject | Neutron guides | en_AU |
dc.subject | Cold neutrons | en_AU |
dc.subject | Neutron reflectors | en_AU |
dc.subject | Surfaces | en_AU |
dc.subject | Interfaces | en_AU |
dc.title | Spatz: the time-of-flight neutron reflectometer with vertical sample geometry at the OPAL research reactor | en_AU |
dc.type | Journal Article | en_AU |
dcterms.dateAccepted | 2022-11-12 | en_AU |