Vortex and unsteady flow measurements with a hot wire anemometer

dc.contributor.authorGuy, TBen_AU
dc.date.accessioned2025-07-25T13:38:34Zen_AU
dc.date.available2025-07-25T13:38:34Zen_AU
dc.date.issued1971-11-29en_AU
dc.date.statistics2024-12-17en_AU
dc.descriptionPhysical copy held by ANSTO Library at DDC: 532/32en_AU
dc.description.abstractA hot wire anemometer can be used to obtain detailed information on the structure of time dependent unsteady flows typical of those produced by the passage of a shock wave along a discontinuous duct. As a timing device, it can also be used to measure the position of shock waves within the flow. When the duct is cylindrical the hot wire anemometer is perhaps the only instrument that can be used. This paper describes a particular application of a method of investigating the unsteady flow within a cylindrical shock tube with an abrupt expansion section. Construction of velocity isopleth diagrams which yield detailed information on the structure of the unsteady flow is also described.en_AU
dc.identifier.booktitle[Proceedings of the] Fourth Australasian Conference on Hydraulics and Fluid Mechanics: at Monash University, Melbourne, Australia, 1971 November 29 to December 3en_AU
dc.identifier.citationGuy, T. B. (1971). Vortex and unsteady flow measurements with a hot wire anemometer. Paper presented to the Fourth Australasian Conference on Hydraulics and Fluid Mechanics, Monash University, Melbourne, Australia, 1971 November 29 to December 3. In [Proceedings of the] Fourth Australasian Conference on Hydraulics and Fluid Mechanics : at Monash University, Melbourne, Australia, 1971 November 29 to December 3. Melbourne: Fourth Australasian Conference on Hydraulics and Fluid Mechanics Organising Committee.en_AU
dc.identifier.conferenceenddate1971-12-03en_AU
dc.identifier.conferencenameFourth Australasian Conference on Hydraulics and Fluid Mechanicsen_AU
dc.identifier.conferenceplaceMelbourne, Australiaen_AU
dc.identifier.conferencestartdate1971-11-29en_AU
dc.identifier.pagination93-100en_AU
dc.identifier.placeofpublicationMelbourne, Australiaen_AU
dc.identifier.urihttps://apo.ansto.gov.au/handle/10238/16347en_AU
dc.language.isoenen_AU
dc.publisherFourth Australasian Conference on Hydraulics and Fluid Mechanics Organising Committeeen_AU
dc.subjectHot Wire Anemometersen_AU
dc.subjectFluid flowen_AU
dc.subjectFluid mechanicsen_AU
dc.subjectMeetingsen_AU
dc.subjectShock wavesen_AU
dc.subjectMeasuring instrumentsen_AU
dc.subjectDuctsen_AU
dc.subjectExpansionen_AU
dc.titleVortex and unsteady flow measurements with a hot wire anemometeren_AU
dc.typeConference Paperen_AU
Files
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: