Abstract: Industrial plant such as heat exchangers and nuclear and conventional boilers are prone to coolant flow oscillations which may not be detected. In this report a hydrodynamic model is formulated in which the one-dimensional non-linear partial differential equations for the conservation of mass energy and momentum are perturbed with respect to time linearised and Laplace-transformed into the s-domain for frequency response analysis. A computer program has been developed to integrate numerically the resulting non-linear ordinary differential equations by finite difference methods. A sample problem demonstrates how the computer code is used to analyse the frequency response and flow stability characteristics of a heated channel.