Repository logo


Status of the x-ray absorption spectroscopy (XAS) beamline at the Australian synchrotron

Abstract

We present herein the current status of the X-ray Absorption Spectroscopy (XAS) Beamline at the 3 GeV Australian Synchrotron. The optical design and performance, details of the insertion device (Wiggler), end station capabilities and construction and commissioning timeline are given.

Description

Citation

Glover, C., McKinlay, J., Clift, J., Barg, M., Boldeman, J., & Ridgway, M., Foran, G., Garrett, R., Lay, P., & Broadbent, A. (2007). Status of the x-ray absorption spectroscopy (XAS) beamline at the Australian synchrotron. Paper presented to the X-Ray Absorption Fine Structure – XAFS13: 13th International Conference, 9th – 14th July 2006, Stanford, California, In B. Hedman & P. Pianetta (Eds.), AIP Conference Proceedings, Volume 882, (pp. 884-886). Stanford, California, United States of America: Stanford University. doi:10.1063/1.2644692

Endorsement

Review

Supplemented By

Referenced By