Browsing by Author "Dipuglia, A"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- ItemCharacterisation and evaluation of a PNP strip detector for synchrotron microbeam radiation therapy(IOP Publishing, 2018-06-21) Davis, JA; Paino, JR; Dipuglia, A; Cameron, M; Siegele, R; Pastuovic, Z; Petasecca, M; Perevertaylo, VL; Rosenfeld, AB; Lerch, MLFThe Quality Assurance requirements of detectors for Synchrotron Micro-beam Radiation Therapy are such that there are limited commercial systems available. The high intensity and spatial fractionation of synchrotron microbeams requires detectors be radiation hard and capable of measuring high dose gradients with high spatial resolution sensitivity. Silicon single strip detectors are a promising candidate for such applications. The PNP strip detector is an alternative design of an already proven technology and is assessed on its contextual viability. In this study, the electrical and charge collection efficiency properties of the device are characterised. In addition, a dedicated TCAD model is used to support ion beam induced charge measurements to determine the spatial resolution of the detector. Lastly, the detector was used to measure the full width half maximum and peak to valley dose ratio for microbeams with only a slight over response. With the exception of radiation hardness the PNP detector is a promising candidate for quality assurance in microbeam radiation therapy. Copyright 2024 IOP Publishing
- ItemIBIC microscopy – the powerful tool for testing micron – sized sensitive volumes in segmented radiation detectors used in synchrotron microbeam radiation and hadron therapies(Elsevier B. V., 2019-11-01) Pastuovic, Z; Davis, J; Tran, LT; Paino, JR; Dipuglia, A; James, B; Povoli, M; Kok, A; Perevertaylo, VL; Siegele, R; Prokopovich, DA; Lerch, MLF; Petasecca, M; Rosenfeld, AB; Cohen, DDIon Beam Induced Charge (IBIC) microscopy performed using highly tuned microbeams of accelerated ions with energies in the MeV range is the powerful tool for analysis of charge carrier transport properties in semiconductor devices based on semiconductor hetero-junction, metal-on-semiconductor and semiconductor-on-insulator configurations. Here we present two cases of recent applications of the IBIC microscopy in the field of medical radiation physics. The reduced-rate ion microbeams with energies in the MeV range and sub-micrometer spot-sizes have been used for the investigations of the charge collection efficiency (CCE) in sensitive volumes of segmented radiation detectors in order to measure the spatial distribution and uniformity of CCE in different polarization conditions. This information allows the determination of the charge carrier transport properties in selected substructures of a particular device and to quantify its ability to accurately determine the energy deposited by incident ionizing radiation - two fundamental requirements of any microdosimeter or detector of ionizing radiation. © 2019 Elsevier B.V.
- ItemX-ray microbeam measurements with a high resolution scintillator fibre-optic dosimeter(Springer Nature, 2017-09-29) Archer, J; Li, E; Petasecca, M; Dipuglia, A; Cameron, M; Stevenson, AW; Hall, CJ; Häusermann, D; Rosenfeld, AB; Lerch, MLFSynchrotron microbeam radiation therapy is a novel external beam therapy under investigation, that uses highly brilliant synchrotron x-rays in microbeams 50 μm width, with separation of 400 μm, as implemented here. Due to the fine spatial fractionation dosimetry of these beams is a challenging and complicated problem. In this proof-of-concept work, we present a fibre optic dosimeter that uses plastic scintillator as the radiation conversion material. We claim an ideal one-dimensional resolution of 50 μm. Using plastic scintillator and fibre optic makes this dosimeter water-equivalent, a very desirable dosimetric property. The dosimeter was tested at the Australian Synchrotron, on the Imaging and Medical Beam-Line. The individual microbeams were able to be resolved and the peak-to-valley dose ratio and the full width at half maximum of the microbeams was measured. These results are compared to a semiconductor strip detector of the same spatial resolution. A percent depth dose was measured and compared to data acquired by an ionisation chamber. The results presented demonstrate significant steps towards the development of an optical dosimeter with the potential to be applied in quality assurance of microbeam radiation therapy, which is vital if clinical trials are to be performed on human patients. © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.