Browsing by Author "Roux, C"
Now showing 1 - 7 of 7
Results Per Page
Sort Options
- ItemBioterrorism: the effects of biological decontamination on the recovery of electronic evidence(Elsevier Ltd, 2011-06-15) Hoile, R; Banos, C; Colella, M; Roux, CThe investigation of a bioterrorism event will ultimately lead to the collection of vital data from electronic devices such as computers and mobile phones. This project sought to determine the use of gamma irradiation and formaldehyde gas as effective biological decontaminants, and the effect of these methods on the recovery of electronic evidence. Electronic items were contaminated with viable spores and then exposed to both decontaminants. Log values for each matrix were calculated with flash drives recording the highest value of 566 Gy for gamma irradiation and a maximum of 50 min exposure to formaldehyde saw the effective destruction of spores. The results indicate that recovery of data varied based on the decontaminant selected, formaldehyde gas giving the most promising results, with electronic data recovered after the required exposure time. Gamma irradiation proved damaging to electronic circuitry at levels required to render the items safe. The implications to computer intelligence and forensics will be discussed based on the outcomes of these findings. © 2011, Elsevier Ltd.
- ItemForensic analysis of explosives using isotope ratio mass spectrometry (IRMS) - discrimination of ammonium nitrate sources(Elsevier, 2009-06) Benson, SJ; Lennard, CJ; Maynard, P; Hill, DM; Andrew, AS; Roux, CAn evaluation was undertaken to determine if isotope ratio mass spectrometry (IRMS) could assist in the investigation of complex forensic cases by providing a level of discrimination not achievable utilising traditional forensic techniques. The focus of the research was on ammonium nitrate (AN), a common oxidiser used in improvised explosive mixtures. The potential value of IRMS to attribute Australian AN samples to the manufacturing source was demonstrated through the development of a preliminary AN classification scheme based on nitrogen isotopes. Although the discrimination utilising nitrogen isotopes alone was limited and only relevant to samples from the three Australian manufacturers during the evaluated time period, the classification scheme has potential as an investigative aid. Combining oxygen and hydrogen stable isotope values permitted the differentiation of AN prills from three different Australian manufacturers. Samples from five different overseas sources could be differentiated utilising a combination of the nitrogen, oxygen and hydrogen isotope values. Limited differentiation between Australian and overseas prills was achieved for the samples analysed. The comparison of nitrogen isotope values from intact AN prill samples with those from post-blast AN prill residues highlighted that the nitrogen isotopic composition of the prills was not maintained post-blast; hence, limiting the technique to analysis of un-reacted explosive material. © 2009, Elsevier Ltd.
- ItemForensic analysis of explosives using isotope ratio mass spectrometry (IRMS) - preliminary study on TATP and PETN(Elsevier, 2009-06) Benson, SJ; Lennard, CJ; Maynard, P; Hill, DM; Andrew, AS; Roux, CThe application of isotopic techniques to investigations requiring the provision of evidence to a Court is limited. The objective of this research was to investigate the application of light stable isotopes and isotope ratio mass spectrometry (IRMS) to solve complex forensic cases by providing a level of discrimination not achievable utilising traditional forensic techniques. Due to the current threat of organic peroxide explosives, such as triacetone triperoxide (TATP), research was undertaken to determine the potential of IRMS to differentiate samples of TATP that had been manufactured utilising different starting materials and/or manufacturing processes. In addition, due to the prevalence of pentaerythritoltetranitrate (PETN) in detonators, detonating cord, and boosters, the potential of the IRMS technique to differentiate PETN samples from different sources was also investigated. Carbon isotope values were measured in fourteen TATP samples, with three definite groups appearing in the initial sample set based on the carbon data alone. Four additional TATP samples (in a second set of samples) were distinguishable utilising the carbon and hydrogen isotopic compositions individually, and also in combination with the oxygen isotope values. The 3D plot of the carbon, oxygen and hydrogen data demonstrated the clear discrimination of the four samples of TATP. The carbon and nitrogen isotope values measured from fifteen PETN samples, allowed samples from different sources to be readily discriminated. This paper demonstrates the successful application of IRMS to the analysis of explosives of forensic interest to assist in discriminating samples from different sources. This research represents a preliminary evaluation of the IRMS technique for the measurement of stable isotope values in TATP and PETN samples, and supports the dedication of resources for a full evaluation of this application in order to achieve Court reportable IRMS results. © 2009, Elsevier Ltd.
- ItemForensic analysis of explosives using isotope ratio mass spectrometry (IRMS)-Part 1: instrument validation of the DELTAplusXP IRMS for bulk nitrogen isotope ratio measurements(Wiley-Blackwell, 2010-01) Benson, SJ; Lennard, CJ; Hill, DM; Maynard, P; Roux, CA significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTAplusXP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA™ 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision/repeatability, reproducibility/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer's uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit-for-purpose in the forensic explosives analysis field. © 2010, Wiley-Blackwell.
- ItemForensic analysis of explosives using isotope ratio mass spectrometry (IRMS)-Part 2: forensic inter-laboratory trial: bulk carbon and nitrogen stable isotopes in a range of chemical compounds (Australia and New Zealand)(Wiley-Blackwell, 2010-01) Benson, SJ; Lennard, CJ; Maynard, P; Hill, DM; Andrew, AS; Neal, K; Stuart-Williams, H; Hope, J; Walker, GS; Roux, CComparability of data over time and between laboratories is a key issue for consideration in the development of global databases, and more broadly for quality assurance in general. One mechanism that can be utilized for evaluating traceability is an inter-laboratory trial. This paper addresses an inter-laboratory trial conducted across a number of Australian and New Zealand isotope ratio mass spectrometry (IRMS) laboratories. The main objective of this trial was to determine whether IRMS laboratories in these countries would record comparable values for the distributed samples. Four carbon containing and four nitrogen containing compounds were distributed to seven laboratories in Australia and one in New Zealand. The laboratories were requested to analyze the samples using their standard procedures. The data from each laboratory was evaluated collectively using International Standard ISO 13528 (Statistical methods for use in proficiency testing by inter-laboratory comparisons). "Warning signals" were raised against one participant in this trial. "Action signals" requiring corrective action were raised against four participants. These participants reviewed the data and possible sources for the discrepancies. This inter-laboratory trial was successful in providing an initial snapshot of the potential for traceability between the participating laboratories. The statistical methods described in this article could be used as a model for others needing to evaluate stable isotope results derived from multiple laboratories, e.g., inter-laboratory trials/proficiency testing. Ongoing trials will be conducted to improve traceability across the Australian and New Zealand IRMS community. © 2010, Wiley-Blackwell. The definitive version is available at www3.interscience.wiley.com
- ItemGamma irradiation as a biological decontaminant and its effect on common fingermark detection techniques and DNA profiling.(Wiley-Blackwell, 2010-01) Hoile, R; Banos, C; Colella, M; Walsh, SJ; Roux, CThe use of disease-causing organisms and their toxins against the civilian population has defined bioterrorism and opened forensic science up to the challenges of processing contaminated evidence. This study sought to determine the use of gamma irradiation as an effective biological decontaminant and its effect on the recovery of latent fingermarks from both porous and nonporous items. Test items were contaminated with viable spores marked with latent prints and then decontaminated using a cobalt 60 gamma irradiator. Fingermark detection was the focus with standard methods including 1,2-indanedione, ninhydrin, diazafluoren-9-one, and physical developer used during this study. DNA recovery using 20% Chelex extraction and quantitative real-time polymerase chain reaction was also explored. Gamma irradiation proved effective as a bacterial decontaminant with D-values ranging from 458 to 500 Gy for nonporous items and 797–808 Gy for porous ones. The results demonstrated the successful recovery of latent marks and DNA establishing gamma irradiation as a viable decontamination option. © 2010, Wiley-Blackwell.
- ItemRecovery of latent fingermarks from evidence exposed to ionizing radiation(Wiley-Blackwell, 2009-05) Colella, M; Parkinson, A; Evans, T; Lennard, C; Roux, CContinual reports of illicit trafficking incidents involving radioactive materials have prompted authorities to consider the likelihood of forensic evidence being exposed to radiation. In this study, we investigated the ability to recover latent fingermark evidence from a variety of substrates that were exposed to ionizing radiation. Fingermarks deposited on common surfaces, including aluminum, glass, office paper, and plastic, were exposed to doses ranging from 1 to 1000 kGy, in an effort to simulate realistic situations where evidence is exposed to significant doses of radiation from sources used in a criminal act. The fingermarks were processed using routine fingermark detection techniques. With the exception of glass and aluminum substrates, radiolysis had a considerable effect on the quality of the developed fingermarks. The damage to ridge characteristics can, in part, be attributed to chemical interactions between the substrate and the components of the fingermark secretions that react with the detection reagents. © 2009, Wiley-Blackwell.