ANSTO Publications Online >
Journal Publications >
Journal Articles >

Please use this identifier to cite or link to this item: http://apo.ansto.gov.au/dspace/handle/10238/6159

Title: Radiation hardness of n-type SiC Schottky barrier diodes irradiated with MeV He ion microbeam
Authors: Pastuovic, Z
Capan, I
Cohen, DD
Forneris, J
Iwamoto, N
Ohshima, T
Siegele, R
Hoshino, N
Tsuchida, H
Keywords: SILICON
HARDNESS
CARBIDES
LAYERS
BEHAVIOR
IRRADIATION
Issue Date: 1-Apr-2015
Publisher: Elsevier Science BV
Citation: Pastuovic, Z., Capan, I., Cohen, D. D., Forneris, J., Iwamoto, N., Ohshima, T., . . . Tsuchida, H. (2015). Radiation hardness of n-type SiC Schottky barrier diodes irradiated with MeV He ion microbeam. Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms, 348, 233-239.
Abstract: We studied the radiation hardness of 4H-SiC Schottky barrier diodes (SBD) for the light ion detection and spectroscopy in harsh radiation environments. n-Type SBD prepared on nitrogen-doped (similar to 4 x 10(14) cm(-3)) epitaxial grown 4H-SiC thin wafers have been irradiated by a raster scanning alpha particle microbeam (2 and 4 MeV He2+ ions separately) in order to create patterned damage structures at different depths within a sensitive volume of tested diodes. Deep Level Transient Spectroscopy (DLTS) analysis revealed the formation of two deep electron traps in the irradiated and not thermally treated 4H-SiC within the ion implantation range (E1 and E2). The E2 state resembles the well-known Z(1/2) center, while the E1 state could not be assigned to any particular defect reported in the literature. Ion Beam Induced Charge (IBIC) microscopy with multiple He ion probe microbeams (1-6 MeV) having different penetration depths in tested partly damaged 4H-SiC SBD has been used to determine the degradation of the charge collection efficiency (CCE) over a wide fluence range of damaging alpha particle. A non-linear behavior of the CCE decrease and a significant degradation of the spectroscopic performance with increasing He ion fluence were observed above the value of 10(11) cm(-2). © 2015 Elsevier B.V.
URI: http://dx.doi.org/10.1016/j.nimb.2014.12.064
http://apo.ansto.gov.au/dspace/handle/10238/6159
ISSN: 0168-583X
Appears in Collections:Journal Articles

Files in This Item:

There are no files associated with this item.

Items in APO are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback