Please use this identifier to cite or link to this item:
https://apo.ansto.gov.au/dspace/handle/10238/304
Title: | Boiling crisis data for vertical upflow of freon-12 in round tubes and annular channels |
Authors: | Stevens, JR Miles, DN |
Keywords: | Boiling Heat transfer Liquid flow Reactor cooling systems Freons |
Issue Date: | Dec-1980 |
Publisher: | Australian Atomic Energy Commission |
Citation: | Stevens, J. R., & Miles, D. N. (1980). Boiling crisis data for vertical upflow of freon-12 in round tubes and annular channels. Lucas Heights, NSW: Australian Atomic Energy Commission. |
Abstract: | Results from boiling crisis (burnout) tests including associated pressure drop data are reported for vertical upflow of Freon-12 at a nominal inlet pressure of 1.0 MPa in three round tube test sections (15 to 21 mm internal diameter heated lengths 2.85 to 3.94 m) and four annular test sections of identical cross section dimensions (16 mm diameter inner tube and 21 mm diameter shroud) with different heated lengths. The tests covered a range of values for coolant flowrate and inlet subcooling. |
Gov't Doc #: | 387 |
URI: | http://apo.ansto.gov.au/dspace/handle/10238/304 |
ISBN: | 0642597022 |
Appears in Collections: | Scientific and Technical Reports |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
AAEC-E-506.pdf | 545.54 kB | Adobe PDF | ![]() View/Open |