Browsing by Author "Wan, S"
Now showing 1 - 1 of 1
Results Per Page
Sort Options
- ItemEffect of x-ray energy on the radiological image quality in propagation-based phase-contrast computed tomography of the breast(Society of Photo-Optical Instrumentation Engineers (SPIE), 2021-07-12) Wan, S; Arhatari, BD; Nesterets, YI; Mayo, SC; Thompson, D; Fox, J; Kumar, B; Prodanovic, Z; Häusermann, D; Maksimenko, A; Hall, CJ; Dimmock, MR; Pavlov, KM; Lockie, D; Rickard, M; Gadomkar, Z; Alaleh, A; Vafa, E; Peele, AG; Quiney, HM; Lewis, SJ; Gureyev, TE; Brennan, PC; Taba, STPurpose: Breast cancer is the most common cancer in women in developing and developed countries and is responsible for 15% of women’s cancer deaths worldwide. Conventional absorption-based breast imaging techniques lack sufficient contrast for comprehensive diagnosis. Propagation-based phase-contrast computed tomography (PB-CT) is a developing technique that exploits a more contrast-sensitive property of x-rays: x-ray refraction. X-ray absorption, refraction, and contrast-to-noise in the corresponding images depend on the x-ray energy used, for the same/fixed radiation dose. The aim of this paper is to explore the relationship between x-ray energy and radiological image quality in PB-CT imaging. Approach: Thirty-nine mastectomy samples were scanned at the imaging and medical beamline at the Australian Synchrotron. Samples were scanned at various x-ray energies of 26, 28, 30, 32, 34, and 60 keV using a Hamamatsu Flat Panel detector at the same object-to-detector distance of 6 m and mean glandular dose of 4 mGy. A total of 132 image sets were produced for analysis. Seven observers rated PB-CT images against absorption-based CT (AB-CT) images of the same samples on a five-point scale. A visual grading characteristics (VGC) study was used to determine the difference in image quality. Results: PB-CT images produced at 28, 30, 32, and 34 keV x-ray energies demonstrated statistically significant higher image quality than reference AB-CT images. The optimum x-ray energy, 30 keV, displayed the largest area under the curve ( AUCVGC ) of 0.754 (p = 0.009). This was followed by 32 keV (AUCVGC = 0.731, p ≤ 0.001), 34 keV (AUCVGC = 0.723, p ≤ 0.001), and 28 keV (AUCVGC = 0.654, p = 0.015). Conclusions: An optimum energy range (around 30 keV) in the PB-CT technique allows for higher image quality at a dose comparable to conventional mammographic techniques. This results in improved radiological image quality compared with conventional techniques, which may ultimately lead to higher diagnostic efficacy and a reduction in breast cancer mortalities.. © 2021 Society of Photo-Optical Instrumentation Engineers (SPIE).