Browsing by Author "Jackson, AJ"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- ItemCombined pressure and temperature denaturation of ribonuclease A produces alternate denatured states(Elsevier, 2016-05-13) Ryan, TM; Xun, Y; Cowieson, NP; Mata, JP; Jackson, AJ; Pauw, BR; Smith, AJ; Kirby, N; McGillivray, DJProtein folding, unfolding and misfolding have become critically important to a range of health and industry applications. Increasing high temperature and high pressure are used to control and speed up reactions. A number of studies have indicated that these parameters can have a large effect on protein structure and function. Here we describe the additive effects of these parameters on the small angle scattering behaviour of ribonuclease A. We find that alternate unfolded structures can be obtained with combined high pressure and temperature treatment of the protein. © 2016 Elsevier Inc.
- ItemThe instrument suite of the European Spallation Source(Elsevier B. V., 2020-01-10) Andersen, KH; Argyriou, DN; Jackson, AJ; Houston, J; Henry, PF; Deen, PP; Toft-Petersen, R; Beran, P; Strobl, M; Arnold, T; Wacklin-Knecht, H; Vivanco, R; Parker, SF; Gussen, A; Kanaki, K; Scionti, G; Olsen, MA; Arai, M; Schmakat, Ph; Lechner, RE; Niedermayer, Ch; Schneider, H; Zanetti, M; Petrillo, C; Moreira, FY; Stepanyan, S; Luna, P; Calzada, E; Stahn, J; Voigt, J; Dupont, T; Hanslik, R; Siemers, DJ; Udby, L; Chowdhury, MAH; Klauser, Ch; Rouijaa, M; Lehmann, E; Heynen, A; Bustinduy, I; Schwaab, A; Raspino, D; Scatigno, C; del Moral, OG; Kiehn, R; Aprigliano, G; Zanatta, M; Huerta, M; Bellissima, S; Lerche, M; Holm-Dahlin, S; Huerta, M; Christensen, NB; Lohstroh, W; Gorini, G; Fenske, J; Hansen, UB; Klauser, C; Rodrigues, S; Müller, M; Gorini, G; Bovo, C; Hall-Wilton, R; Fabrèges, X; Siemers, DJ; Khaplanov, A; Tsapatsaris, N; Taylor, J; Christensen, M; Schefer, J; Woracek, R; Tozzi, P; Müller, M; Carlsen, H; Olsen, MA; Orecchini, A; Di Fresco, L; Paciaroni, A; Bovo, C; Magán, M; Hauback, BC; Elmer, J; Heenan, RK; Piscitelli, F; Masi, F; Bakedano, G; Klimko, S; De Bonis, A; Fedrigo, A; Lukáš, P; Frielinghaus, H; Stahn, J; Schweika, W; Markó, M; Pfeiffer, D; Kirstein, O; Di Fresco, L; Schreyer, A; Orszulik, A; Nowak, G; Butterweck, S; Šaroun, J; Paciaroni, A; Kolevatov, R; Lehmann, EH; Filges, U; Schreyer, A; Koenen, M; Bustinduy, I; Magán, M; Feygenson, M; Cooper, JFK; Abad, E; Senesi, R; Longeville, S; Llamas-Jansa, I; Schulz, M; Birk, JO; Sharp, M; Galsworthy, P; Šaroun, J; Martínez, J; Hiess, A; Holm-Dahlin, S; Filges, U; Pullen, SA; Guyon Le Bouffy, J; Schefer, J; Lukáš, P; Udby, L; Kozielewski, T; Niedermayer, C; Sacchetti, F; Hartl, M; Jaksch, S; Salhi, Z; Brückel, T; Aguilar, J; Aguilar, J; Seifert, M; Bordallo, HN; Robillard, T; Villacorta, FJ; Herranz, I; del Rosso, L; Hauback, BC; Orecchini, A; Fabrèges, G; Fenske, J; Neuhaus, J; Schillinger, B; Abad, E; Kittelmann, T; Lefmann, K; Seifert, M; Neuhaus, J; Herranz, I; Kolevatov, R; Annighöfer, B; Oksanen, E; Morgano, M; Laszlo, G; Freeman, PG; Kennedy, SJ; Bertelsen, M; Bellissima, S; Alba-Simionesco, C; Markó, M; Mezei, F; Chowdhury, M; Halcrow, W; Jestin, J; Lieutenant, K; Babcock, E; Rønnow, HM; Engels, R; del Moral, OG; Vickery, A; Rouijaa, M; Lavie, P; Petersson Årsköld, S; Glavic, A; Désert, S; Mannix, D; Scatigno, C; Petry, W; Christensen, NB; Violini, N; Villacorta, FJ; Porcher, F; Glavic, A; Scionti, G; Zanetti, M; Fernandez-Alonso, F; Rønnow, HM; Mosconi, M; Olsson, M; Stepanyan, S; Petrillo, C; del Rosso, L; Harbott, P; Sacchetti, F; Bertelsen, M; Kämmerling, H; Andreani, C; Schulz, M; Colognesi, D; Luna, P; Loaiza, L; Turner, D; Martínez, JL; Tartaglione, A; Sordo, F; Llamas-Jansa, I; Schmakat, P; Lechner, RE; Poqué, A; Fernandez-Alonso, F; Colognesi, D; Tartaglione, A; Morgano, M; Webb, N; Loaiza, L; Whitelegg, L; Petry, W; Iversen, K; Vivanco, R; Tozzi, P; Goukassov, A; Schillinger, B; Carlsen, H; Masi, F; Christensen, M; Nowak, G; Nightingale, J; Schütz, S; Lopez, CI; Langridge, S; Schütz, S; Nagy, G; Zanatta, M; Andreani, C; Lefmann, K; Lohstroh, W; Mosconi, M; Senesi, R; Stefanescu, I; Bakedano, G; Hagen, ME; Wischnewski, A; Bourges, P; Hansen, UB; De Bonis, A; Kiehn, R; Parker, SF; Iversen, K; Sordo, F; Freeman, PG; Birk, JO; Rodríguez, DM; Ansell, SAn overview is provided of the 15 neutron beam instruments making up the initial instrument suite of the European Spallation Source (ESS), and being made available to the neutron user community. The ESS neutron source consists of a high-power accelerator and target station, providing a unique long-pulse time structure of slow neutrons. The design considerations behind the time structure, moderator geometry and instrument layout are presented. The 15-instrument suite consists of two small-angle instruments, two reflectometers, an imaging beamline, two single-crystal diffractometers; one for macromolecular crystallography and one for magnetism, two powder diffractometers, and an engineering diffractometer, as well as an array of five inelastic instruments comprising two chopper spectrometers, an inverse-geometry single-crystal excitations spectrometer, an instrument for vibrational spectroscopy and a high-resolution backscattering spectrometer. The conceptual design, performance and scientific drivers of each of these instruments are described. All of the instruments are designed to provide breakthrough new scientific capability, not currently available at existing facilities, building on the inherent strengths of the ESS long-pulse neutron source of high flux, flexible resolution and large bandwidth. Each of them is predicted to provide world-leading performance at an accelerator power of 2 MW. This technical capability translates into a very broad range of scientific capabilities. The composition of the instrument suite has been chosen to maximise the breadth and depth of the scientific impact of the early years of the ESS, and provide a solid base for completion and further expansion of the facility. © 2020 The Authors. Published by Elsevier B.V. Open access article under the CC BY-NC-ND license.
- ItemLearning about SANS instruments and data reduction from round robin measurements on samples of polystyrene latex(Wiley Blackwell, 2013-10-01) Rennie, AR; Hellsing, MS; Wood, K; Gilbert, EP; Porcar, L; Schweins, R; Dewhurst, CD; Lindner, P; Heenan, RK; Rogers, SE; Butler, PD; Krzywon, JR; Ghosh, RE; Jackson, AJ; Malfois, MMeasurements of a well-characterized 'standard' sample can verify the performance of an instrument. Typically, small-angle neutron scattering instruments are used to investigate a wide range of samples and may often be used in a number of configurations. Appropriate 'standard' samples are useful to test different aspects of the performance of hardware as well as that of the data reduction and analysis software. Measurements on a number of instruments with different intrinsic characteristics and designs in a round robin can not only better characterize the performance for a wider range of conditions but also, perhaps more importantly, reveal the limits of the current state of the art of small-angle scattering. The exercise, followed by detailed analysis, tests the limits of current understanding as well as uncovering often forgotten assumptions, simplifications and approximations that underpin the current practice of the technique. This paper describes measurements of polystyrene latex, radius 720 angstrom, with a number of instruments. Scattering from monodisperse, uniform spherical particles is simple to calculate and displays sharp minima. Such data test the calibrations of intensity, wavelength and resolution as well as the detector response. Smoothing due to resolution, multiple scattering and polydispersity has been determined. Sources of uncertainty are often related to systematic deviations and calibrations rather than random counting errors. The study has prompted development of software to treat modest multiple scattering and to better model the instrument resolution. These measurements also allow checks of data reduction algorithms and have identified how they can be improved. The reproducibility and the reliability of instruments and the accuracy of parameters derived from the data are described. © 2013, Wiley-Blackwell.