Browsing by Author "Chacon, A"
Now showing 1 - 4 of 4
Results Per Page
Sort Options
- ItemDetection and discrimination of neutron capture events for NCEPT dose quantification(Springer Nature Limited, 2022-04-07) Chacon, A; Kielly, M; Rutherford, H; Franklin, DR; Caracciolo, A; Buonanno, L; D'Adda, I; Rosenfeld, AB; Guatelli, S; Carminati, M; Fiorini, C; Safavi-Naeini, MNeutron Capture Enhanced Particle Therapy (NCEPT) boosts the effectiveness of particle therapy by capturing thermal neutrons produced by beam-target nuclear interactions in and around the treatment site, using tumour-specific 10B or 157Gd-based neutron capture agents. Neutron captures release high-LET secondary particles together with gamma photons with energies of 478 keV or one of several energies up to 7.94 MeV, for 10B and 157Gd, respectively. A key requirement for NCEPT’s translation is the development of in vivo dosimetry techniques which can measure both the direct ion dose and the dose due to neutron capture. In this work, we report signatures which can be used to discriminate between photons resulting from neutron capture and those originating from other processes. A Geant4 Monte Carlo simulation study into timing and energy thresholds for discrimination of prompt gamma photons resulting from thermal neutron capture during NCEPT was conducted. Three simulated 300×300×300 mm3 cubic PMMA targets were irradiated by 4He or 12C ion beams with a spread out Bragg peak (SOBP) depth range of 60 mm; one target is homogeneous while the others include 10×10×10 mm3 neutron capture inserts (NCIs) of pure 10B or 157Gd located at the distal edge of the SOBP. The arrival times of photons and neutrons entering a simulated 50×50×50 mm3 ideal detector were recorded. A temporal mask of 50–60 ns was found to be optimal for maximising the discrimination of the photons resulting from the neutron capture by boron and gadolinium. A range of candidate detector and thermal neutron shielding materials were simulated, and detections meeting the proposed acceptance criteria (i.e. falling within the target energy window and arriving 60 ns post beam-off) were classified as true or false positives, depending on their origin. The ratio of true/false positives (RTF) was calculated; for targets with 10B and 157Gd NCIs, the detector materials which resulted in the highest RTF were cadmium-shielded CdTe and boron-shielded LSO, respectively. The optimal irradiation period for both carbon and helium ions was 1 µs for the 10B NCI and 1 ms for the 157Gd NCI. © The Authors, Creative Commons Attribution 4.0 International Licence.
- ItemErratum: Influence of momentum acceptance on range monitoring of 11C and 15O ion beams using in-beam PET (2020 Phys. Med. Biol. 65 125006)(IOP Publishing, 2020-11-21) Mohammadi, A; Tashima, H; Iwao, Y; Takyu, S; Akamatsu, G; Kang, HG; Nishikido, F; Yoshida, E; Chacon, A; Safavi-Naeini, M; Parodi, K; Yamaya, TIn heavy-ion therapy, the stopping position of primary ions in tumours needs to be monitored for effective treatment and to prevent overdose exposure to normal tissues. Positron-emitting ion beams, such as 11C and 15O, have been suggested for range verification in heavy-ion therapy using in-beam positron emission tomography (PET) imaging, which offers the capability of visualizing the ion stopping position with a high signal-to-noise ratio. We have previously demonstrated the feasibility of in-beam PET imaging for the range verification of 11C and 15O ion beams and observed a slight shift between the beam stopping position and the dose peak position in simulations, depending on the initial beam energy spread. In this study, we focused on the experimental confirmation of the shift between the Bragg peak position and the position of the maximum detected positron-emitting fragments via a PET system for positron-emitting ion beams of 11C (210 MeV u−1) and 15O (312 MeV u−1) with momentum acceptances of 5% and 0.5%. For this purpose, we measured the depth doses and performed in-beam PET imaging using a polymethyl methacrylate (PMMA) phantom for both beams with different momentum acceptances. The shifts between the Bragg peak position and the PET peak position in an irradiated PMMA phantom for the 15O ion beams were 1.8 mm and 0.3 mm for momentum acceptances of 5% and 0.5%, respectively. The shifts between the positions of two peaks for the 11C ion beam were 2.1 mm and 0.1 mm for momentum acceptances of 5% and 0.5%, respectively. We observed larger shifts between the Bragg peak and the PET peak positions for a momentum acceptance of 5% for both beams, which is consistent with the simulation results reported in our previous study. The biological doses were also estimated from the calculated relative biological effectiveness (RBE) values using a modified microdosimetric kinetic model (mMKM) and Monte Carlo simulation. Beams with a momentum acceptance of 5% should be used with caution for therapeutic applications to avoid extra dose to normal tissues beyond the tumour when the dose distal fall-off is located beyond the treatment volume. © 2020 Institute of Physics and Engineering in Medicine.
- ItemGd-TPP-DOTA reduces cell viability in cancer cells via synchrotron radiotherapy(Australian National University, 2021-08-24) Middleton, RJ; Howell, NR; Livio, E; Wyatt, NA; Chacon, A; Fraser, BH; Barnes, M; Cameron, M; Rendina, LM; Häusermann, D; Lerch, M; Safavi-Naeini, MHigh-Z elements have been proposed as radiosensitisers in X-ray photon radiotherapy due to their emission of multiple high-LET photo- and Auger electrons following X-ray irradiation. Gadolinium is a particularly attractive candidate radiosensitiser, since it can also be used as an MRI contrast agent. In this study, we report on the efficacy of Gd-triphenylphosphonium salt-DOTA (Gd(III)-TPP-DOTA) for synchrotron microbeam radiation therapy dose enhancement. The compound utilises the mitochondrial targeting moiety triphenylphosphonium (TPP) to accumulate Gd in the inner mitochondrial membrane. Experiments were conducted using the dynamic mode option at hutch 2B of the Imaging and Medical Beamline at the Australian Synchrotron. Human glioblastoma multiforme cells (T98G cell line) were cultured to 80-90% confluence in T12.5 flasks. Approximately 24 hours prior to irradiation, the cultures were either treated with a 500 μM solution of Gd(III)DOTA-TPP or a vehicle control. Spatial dose distribution of synchrotron broad beam (BB) and single/multiple microbeams were measured using a micron-scale X-Tream dosimetry system and Gafchromic films in air and at 2 cm depth in solid water (same depth as the monolayer of cells in T12.5 flasks). A total of 96 flasks were irradiated, with doses of 0, 1, 2, 3, 4, 5, 10 and 16 Gy delivered in valley (MRT) or uniformly (BB). Post irradiation, each flask was re-seeded into 7 x 96 well-plates to perform the resazurin cell proliferation assay up to 7 days after irradiation. Our preliminary analysis indicates that for cells irradiated by 3 Gy of BB or MRT radiation, the addition of Gd(III)DOTA-TPP results in a reduction in viable cell mass by 24.25% and 25.79%, respectively, compared with untreated flasks. © The Authors
- ItemInfluence of momentum acceptance on range monitoring of 11C and 15O ion beams using in-beam PET(IOP Publishing, 2020-06-12) Mohammadi, A; Tashima, H; Iwao, Y; Takyu, S; Akamatsu, G; Kang, HG; Nishikido, F; Yoshida, E; Chacon, A; Safavi-Naeini, M; Parodi, K; Yamaya, TIn heavy-ion therapy, the stopping position of primary ions in tumours needs to be monitored for effective treatment and to prevent overdose exposure to normal tissues. Positron-emitting ion beams, such as 11C and 15O, have been suggested for range verification in heavy-ion therapy using in-beam positron emission tomography (PET) imaging, which offers the capability of visualizing the ion stopping position with a high signal-To-noise ratio. We have previously demonstrated the feasibility of in-beam PET imaging for the range verification of 11C and 15O ion beams and observed a slight shift between the beam stopping position and the dose peak position in simulations, depending on the initial beam energy spread. In this study, we focused on the experimental confirmation of the shift between the Bragg peak position and the position of the maximum detected positron-emitting fragments via a PET system for positron-emitting ion beams of 11C (210 MeV u-1) and 15O (312 MeV u-1) with momentum acceptances of 5% and 0.5%. For this purpose, we measured the depth doses and performed in-beam PET imaging using a polymethyl methacrylate (PMMA) phantom for both beams with different momentum acceptances. The shifts between the Bragg peak position and the PET peak position in an irradiated PMMA phantom for the 15O ion beams were 1.8 mm and 0.3 mm for momentum acceptances of 5% and 0.5%, respectively. The shifts between the positions of two peaks for the 11C ion beam were 2.1 mm and 0.1 mm for momentum acceptances of 5% and 0.5%, respectively. We observed larger shifts between the Bragg peak and the PET peak positions for a momentum acceptance of 5% for both beams, which is consistent with the simulation results reported in our previous study. The biological doses were also estimated from the calculated relative biological effectiveness (RBE) values using a modified microdosimetric kinetic model (mMKM) and Monte Carlo simulation. Beams with a momentum acceptance of 5% should be used with caution for therapeutic applications to avoid extra dose to normal tissues beyond the tumour when the dose distal fall-off is located beyond the treatment volume. © 2020 Institute of Physics and Engineering in Medicine